2. Fitting and pneumatic installation
2.5

Mounting the CASM sensor interface

1
Mounting screw
(connect
earthing)
Fig. 2/7: Mounting the CASM
1
H−rail
Fig. 2/8: Mounting the CASM on H−rail
2−22
Mount the CASM−... sensor interface on an even surface with
two M4 screws and one retaining washer each. See Fig. 2/7.
The
symbol marks the position of the mounting screws.
The outer mounting screw also serves for earthing (
Tightening torque: 2 Nm.
1
Mounting on H−rails as per EN 60715 is possible with
mounting kit CP−TS−HS35. See Fig. 2/8.