Festo CPX Instructions And Assembly

Festo CPX Instructions And Assembly

Terminal cpx / valve terminal mpa
Hide thumbs Also See for CPX:

Advertisement

Quick Links

CPX, CPX-M, MPAL-VI, MPA-F, MPA-S
Terminal CPX / Valve terminal MPA
Instructions | Assembly
8085254
2019­01a
[8085256]
Translation of the original instructions
1

Applicable documents

All available documents for the product è www.festo.com/pk.
Document
Product
Description
Terminal CPX
Description
Valve terminal MPAL­VI
Description
Valve terminal MPA­F
Description
Valve terminal MPA­S
Tab. 1
2

Safety

2.1

Safety instructions

Only assemble the product on components that are in a condition to be safely
operated.
Observe the handling specifications for electrostatically sensitive devices.
Plan sufficient space:
Enable heat dissipation by air circulation è 1 Applicable documents
Ensure that the connections are accessible
Requirements for the mounting surface:
torsion­free operation of the product
support of the weight and other forces occurring during operation
2.2

Intended use

The CPX terminal with valve terminal MPA 1 is referred to as CPX terminal 1 in
this instruction manual.
Product
Use
CPX terminal 1
Control of pneumatic actuators. Query of the sensors.
Additional wall mounting of the valve terminal 1.
2/3/5/6/8/aJ
Tab. 2
3

Product range overview

3.1

Scope of delivery

Fig. 1
Mounting for CPX modules (plastic):
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347­0
www.festo.com
8085254
Contents
System, Assembly, Installation, Com­
missioning
System, Assembly, Installation, Com­
missioning, conversion, disassembly
1 Terminal
CPX
with
Valve terminal
MPA
Fig. 2
Mounting for CPX modules (metal):
Fig. 3
Mounting for MPAL­VI modules
Fig. 4
Mounting for MPA­F modules
Fig. 5
Mounting for MPA­S proportional­pressure regulator
Fig. 6
Mounting for MPA­S intermediate supply (pneumatic supply plate)
Fig. 7
3.2
Not included
Fig. 8
Mounting CPX­CPA­BG­NRH
Fig. 9
Mounting VMPAF­FB­BG­NRH
2 Mounting
CPX­BG­RW­...
3 Mounting bracket
CPX­M­BG­RW­...
4 Screw M3
(thread­cutting)
5 Mounting bracket
VMPAL­BD
6 Mounting bracket
VMPAF­BG­RW­...
7 Screw M4
(thread­cutting)
8 Mounting bracket
VMPA­BG
9 Screw M3
(thread­cutting)
10 Mounting bracket
VMPA­BG­RW­...
11 Screw M3
(thread­cutting)
12 H­rail (1x)
EN 60715 ­ 35x7.5 or 35x15
13 Screw (3x)
14 Clamping element (3x)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPX and is the answer not in the manual?

Questions and answers

Summary of Contents for Festo CPX

  • Page 1 12 H­rail (1x) EN 60715 ­ 35x7.5 or 35x15 Intended use The CPX terminal with valve terminal MPA 1 is referred to as CPX terminal 1 in this instruction manual. Product CPX terminal 1 Control of pneumatic actuators.
  • Page 2 3. Install additional mounting 2 opposite. 4.1.2.2 Mounting [3] on CPX modules (metal) For CPX modules (metal) without system supply, the mounting 3 can be assembled on both sides of the module. Fig. 11 1. Check positions of the pre­assembled mountings and correct if required.
  • Page 3 4.1.2.4 Mounting [6] on MPA-F modules 4.1.3.1 Mounting points of the CPX terminal (plastic) with MPAL-VI valve terminal Fig. 18 Mounting point Screw size Number 1x every 2 1x every 5 Fig. 15 1. Place mounting 6 on the module [D]. Tab. 5 2.
  • Page 4 4.1.3.4 Mounting points of the CPX terminal (plastic) with 4.2.2.1 H-rail mounting with MPAL-VI or MPA-F valve terminal MPA-S valve terminal Fig. 21 Mounting point Screw size Number 1x every 2 1x every aJ 1x every 8 Tab. 8 4.1.3.5...
  • Page 5 4.2.2.2 H-rail mounting with MPA-S valve terminal Fig. 35 Tightening the screws aC turns the clamping elements aD 90°. CPX terminal 1 is secured against tilting and slipping. Technical data Vibration resistance/ according to IEC 60068...
  • Page 6 Features of severity level (SL) Vibration load Frequency range [Hz] Acceleration [m/s Deflection [mm] 2 … 8 2 … 8 – – ±3.5 ±3.5 8 … 27 8 … 27 – – 27 … 58 27 … 60 – – ±0.15 ±0.35 58 … 160 60 … 160 – – 160 … 200 160 … 200 – – Shock load Acceleration [m/s Duration [ms] Shocks per direction...

This manual is also suitable for:

Cpx-mMpal-viMpa-fMpa-s

Table of Contents