Download Print this page

System Control - Festo SPC200 Series Quick Reference

Hide thumbs Also See for SPC200 Series:

Advertisement

Available languages

Available languages

SPC200-...
Recommendation (for first commissioning):
Determine the test program entered as start program A.
Deactivate start program B (Startpr. B=***).
Set the operating mode Start/Stop. Programs can then be
controlled independently of a higher-order PLC/IPC e.g. with
the control panel (easier test possibilities).
4. Load the settings into the SPC200 with "Download."
5. Accept the settings with "OK". Save any modifications to the
project (with active project window, command [File] [Save]).
Step 9: Test the program in Debug mode or in continuous
run
Requirements:
– the program must be in program memory
– the axis and application parameters must be set and the
project loaded into the SPC200
– the operating mode Start/Stop and the start program must
be set
– There must be a 1-signal at ENABLE and STOP.
Test the program in Debug mode
Test the program with the Debug mode in WinPISA (com-
mand [Online] [Control axes] or with the control panel (com-
mand SINGLE STEP, TEST/DIAG).
Start the program
Start the program with a rising edge at the START input or
with the control panel (command START SYSTEM, menu

SYSTEM CONTROL).

22