Primus XCONTROL PLUS Original Programming Manual page 92

Industrial washer extractors
Table of Contents

Advertisement

FAILURE 81: NO REHEAT
Traceability only. Failure 81 occurs when the heating is not restarted (at the wash sequence) when the
water temperature of the bath is below its normal programmed value. When the temperature drops below the
predefined temperature limit of a hygienic wash cycle, the wash cycle can not be validated for hygienic reasons
as the wash process has not followed the standards of the wash program in execution. This means that the
linen must be washed again after repairing the problem with the heating system.
DIAGNOSE:
Check Diagnostics Failure 13 : Heating Failure, and Failure 14 : Heating Time Failure
FAILURE 82: NO REFILL
Traceability only. Failure 82 occurs when the water filling is not restarted (at the wash sequence) when the
water level of the bath is below its normal programmed value. When the water level drops below the
predefined water level limit of a hygienic wash cycle, the wash cycle can not be validated for hygienic
reasons as the wash process has not followed the standards of the wash program in execution. This means
that the linen must be washed again after repairing the problem with the water fill system.
DIAGNOSE:
Check Diagnostics Failure 11 : Fill Failure
FAILURE 83: CYCLE FAIL
Traceability only. Failure 83 occurs when the wash cycle can not be validated for hygienic reasons as the
wash process has not followed the standards of the wash program in execution. This means that the linen
must be washed again after repairing the problem. The Error message is only for information purposes and
at the end of the wash cycle the operator will get a warning the wash cycle must be repeated.
DIAGNOSE:
See Extra Error message that shows the cause of the failure.
FAILURE 85: RTC LOW BATTERY
Failure 85 occurs when there is no battery available at the real time clock, or if the power of the battery is too
small to make the real time clock run correctly.
DIAGNOSE:
Replace the CPU board.
92
PROGRAMMING MANUAL
540876_A_PUB_DATE_1_FEB_2012.DOC