6.13. COOLDOWN FUNCTION
AUTOMATIC COOLDOWN : this function avoids thermal shock in the washing machine.
For Hot washes above 65°C, Cold water is added at the end of the step.
PROGRAMMED COOLDOWN : this function is recommended to avoid the shrinking of the
garments.
Water is drained and cold water is added bit by bit. The temperature of the water in the
tub will decrease slowly as a function of the programmed Cool-down Sequence
(temperature and time).
6.14. SPRAY FUNCTION
The special product is injected while the drain valve is open and depending the
programmed speed, the drum will spin at distribution or low spin speed.
6.15. UNBALANCE
When the machine is badly loaded during the spin sequence, then the tilt switch will get
activated.
The spin sequence will be interrupted and the garments in the drum will be redistributed.
The washing machine will try up to 5 times to redistribute the garments.
6.16. PAUSE
When a signal has been programmed, at the end of a wash sequence, the machine will
stop the Program and the message „Pause, Press Start to Continue" will be displayed.
The buzzer will give a warning for the operator.
Now the operator can add Soap.
By pressing the START button the PROGRAM will go on with the next Program step.
6.17. STOP
By pressing the STOP button the program is interrupted.
First the machine will go over to a safe state.
Then the message CONTINUE ? is displayed.
STOP : the program is stopped. (A tumble sequence will be executed before the door can be
opened.)
START : the program restarts the last active step, and goes on with the rest of the program.
6.18. WAIT STATE
It can occur that the normal machine operation has been interrupted and that you have to
wait until the Wash Computer allows you to go on.
You can recognize the wait state by a display that shows WAIT and a decreasing counter.
This will occur when the power has been switched off and on at a running wash cycle.
As the software doesn't know how fast the motor was spinning, a delay time is respected
before the machine can be restarted.
54
PROGRAMOVACÍ MANUÁL
540876_A_PUB_DATE_1_FEB_2012.DOC