FAILURE 32: VERIFICATION FAULT INVERTER
Fault 32 occurs if a wrong parameter is detected at the verification of the inverter parameters. After writing
the inverter parameters in the inverter, the parameters are verified one by one to ensure that they have been
correctly loaded. This fault message means that at least one of the dedicated inverter parameters is wrong.
As a result the inverter will not work in a correct way.
DIAGNOSE:
1. Check if the correct machine type
is selected in the Configuration Menu.
2. Check if the door is closed and locked.
3. Check if the inverter is energized.
4. Write the parameters once more
into the inverter.
FAILURE 35: WRONG SOFTWARE VERSION
When a totally new software that isn't backward compatible with previous software versions is loaded, then
the software will detect that the old and new software's are not compatible.
You have to reconfigure the Wash Computer. See Chapter 4.
ATTENTION!
!
ALL THE CUSTOM SETTINGS WILL BE ERASED IN THE WASH COMPUTER BY LOADING THE FACTORY
SETTINGS.
After reconfiguration of the Wash Computer, fault 35 can only be erased by switching the power Off/On.
FAILURE 37: DRAIN FAILURE AT THE SPRAY SEQUENCE
Failure 37 occurs when the electronic timer detects that the water is not drained after 3 minutes at the Spray
Sequence.
DIAGNOSE:
1. Check the drain tube of the washing machine.
2. Check the drain valve.
3. Check the wiring:
When the drain valve is switched Off, the drain
valve should be open. (normal open)
FAILURE 39: EMPTY SOAP SUPPLY BOX
Failure 39 occurs when the electronic timer detects that the Soap Reservoir is empty.
To avoid that No Liquid Soap is added at the wash process, the operator gets a warning when a Liquid Soap
Supply Reservoir is almost empty.
DIAGNOSE:
1. Check if the Liquid Soap Supply is empty.
90
If the wrong machine type is selected, enter the right
machine type.
If the door is not closed, close the door.
If the door is not locked, repair the door lock system.
If the inverter is not energized, check the power to the
inverter (see fault 27).
If the fault is persistent, contact the manufacturer.
If the drain tube is blocked: repair the drain tube.
If the drain valve is defective: replace the drain valve.
If the wiring is damaged: repair the wiring.
Add Soap to the Liquid Soap Supply System.
PROGRAMMING MANUAL