 TOOLBOX MENU
The purpose of the Toolbox Menu is to give support at technical interventions.
Menu Item
View Input States ?
1 Input 1
...
20 Input 20
Imbalance Statistics ...
Imbalance ...
1 ...0,5
0
...
31 > 15
0
Current ...
1 I0
0
...
4 I3
0
Inverter Power
Pulley Ratio
RTC Time
RTC Date
Adjust Clock ...
Hour
Minutes
Day
Month
Year
76
Info
The Input states for Input 1, ..., Input 20.
The exact function of the inputs can be found on the
On
electrical drawing of the washing machine programmer.
- if the Input state is Off, the Input signal is low.
Off
- if the input state is On, the Input signal is high.
Diagnostic information on imbalance of the machine.
Off
By this function it's possible to switch on the power of
the inverter if a technical intervention is needed.
Attention!
!
SPECIAL CARE HAS BEEN TAKEN AT THE INITIALIZATION
OF THE PARAMETERS OF THE FREQUENCY INVERTER.
THE MANUFACTURER IS NOT RESPONSIBLE FOR THE
WRONG BEHAVIOR OF THE WASHING MACHINE IF THE
OWNER HAS INSTALLED NEW PARAMETER SETTINGS IN
THE INVERTER THAT DO NOT CORRESPOND WITH THE
ORIGINAL SETTINGS AT THE FACTORY.
X.XX
The Pulley Ratio allows to verify if the motor pulley
and the drum pulley have the correct size by
calculating the pulley ratio.
XX:YY:ZZ
The Time value of the Real Time Clock.
XX : Hours, YY : Minutes, ZZ : Seconds
AA:BB:CC
The Date value of the Real Time Clock.
AA : Day, BB : Month, CC : Year
Set the correct Date and Time for the RTC.
XX
YY
AA
BB
CC