ATTENTION!
!
FOR MACHINES WITH LIQUID SUPPLY PUMPS, DIRECT WATER INLET VALVE 7 MUST BE
PROGRAMMED BECAUSE THE LIQUID IS ADDED AT THE DIRECT WATER INLET CHANNEL.
FOR WASHING MACHINES WITH WATER RECYCLING, THE WATER RECYCLING SUPPLY MUST
BE CONNECTED TO INLET VALVE 5 OR 7.
 Programming the water level
– Water level Limits
 See table 3.5. A. The values are different for each machine type.
 Minimum value: above the heating elements and the temperature sensor
 Maximum value: half the wash drum
– Normal Low Level, Normal High Level
 The Normal Low Level is recommended for the PREWASH, WASH and SOAK sequences.
 The Normal High Level is recommended for the RINSE and FINAL RINSE Sequences.
 At the COOLDOWN sequence, the Wash Computer makes use of a low water level and is
draining the water automatically.
 At the Spray sequence, the Drain valve stays open.
– Wet Cleaning selection Configuration menu
 It's possible to program a level below default minimum programmable level. (see table 3.5.A).
 The heating will not be functional for a water level below the standard minimum
programmable water level.
ATTENTION!
!
FOR WOOLENS AND OTHER DELICATE LINEN A NORMAL HIGH WATER LEVEL IS RECOMMENDED.
THE ECONOMY WASH PROGRAMS SHOULD ONLY BE USED FOR LIGHTLY SOILED AND/OR
SMALLER VOLUMES OF LAUNDRY. IN OTHER CASES, THE PROGRAM WILL GIVE POOR WASHING
QUALITY.