Primus XCONTROL PLUS Original Programming Manual page 75

Industrial washer extractors
Table of Contents

Advertisement

Menu Item
Software XXX Version: 771.100.0
 FAULTS MENU (SERVICE FAULTS)
Menu Item
View Fault Messages ...
1 Fault 1: E XXX: YYYYYYYYYYYY
...
20 Fault: E XXX: YYYYYYYYYYYY
Erase Fault Messages
View Fault Statist ...
1 No Drain
...
540876_A_PUB_DATE_1_FEB_2012.DOC
Info
The software version number.
Info
- check the last 20 fault messages from the Err log
Fault N° 1 : the last occurred error message
...
Fault N° 20 : the last - 20 occurred error message
E XXX : The Error message number
YYYYYYYYYYYY : The Error message name
(If no messages are displayed, this means that no Errors have
occurred.)
No
- the Error log is reset by erasing the Fault Messages.
The Fault Statistics are an accumulation of Error
messages that have appeared over a long period.
0x
With this information the technician has an indication
on which parts an intervention should be needed.
(the statistics are reset by the „Reset Service Counts" menu item
in the toolbox menu)
The List with Statistics :
 No Drain
 Door Switch
 No Fill
 No Heating
 Temp Sensor
 Level Sensor
 Out of balance switch
 Invert Com
 Invert Alarm
 Invert OV Alarm
PROGRAMOVACÍ MANUÁL
TROUBLESHOOTING
: E2 + E37
: E6 + E7 + E8 + E9
: E11 + E40
: E13 + E14
: E25
: E24
: E3
: E27
: E26 + E28 + E29 +
E72 + E73 + E74 + E75
: E303 + E304 + E305
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents