Primus XCONTROL PLUS Original Programming Manual page 42

Industrial washer extractors
Table of Contents

Advertisement

 THE COOLDOWN SEQUENCE
Cooldown
Prewash
| Wash |
 After a Hot wash you can program a Cool-down Sequence to avoid temperature shock and
shrinking of the garments.
 The drain step after the Hot wash must be put on NO DRAIN.
 No inlets are programmable :
- machine with three water inlets: inlet 7 is the standard inlet.
- machine with two water inlets: inlet 1 is the standard inlet.
 The water level can't be programmed as the process of adding and draining water doesn't allow this.
ATTENTION!
!
DO NOT PROGRAM A DRAIN SEQUENCE BEFORE A COOLDOWN SEQUENCE
Menu Item
Temperature
RPM
Drain Valve
On Time
Off Time
Time
Signal
42
| Rinse |
Final Rinse
| Soak | Spray | No wash
Default
Info
60 °C
The water temperature.
-
The suggested RPM depends on the machine Type.
1
Only available on washing machines with both : a
normal Open and normal Closed Drain valve.
12 sec
The wash action, motor On Time.
Gentle wash action : 3 sec.
(The suggested default values can be adjusted at the Initialization menu)
3 sec
The wash action, motor Off Time.
Gentle wash action : 12 sec.
(The suggested default values can be adjusted at the Initialization menu)
7.0 Min
The programmed time = time needed to decrease the
water temperature.
Once the programmed temperature has been reached,
the next Sequence will be started.
(for 0 Minutes the Cooldown sequence will be skipped)
(programmable in steps of 0,5 Minutes)
Attention!
!
If a short time is programmed, the water temperature will
decrease fast.
Recommendation!
Program 1 minute for each 3°C temperature drop.
Example :
For a hot wash of 90°C and a Cooldown Sequence of 60°C a
time of about 30°C/3°C = 10 Minutes should be programmed
for the Cooldown Sequence.
No
When a signal is programmed, a pause will be
introduced at the end of the Wash Step. This allows
the operator to add soap for the next step. A buzzer
signal warns the operator that the cycle has been
interrupted.
PROGRAMOVACÍ MANUÁL
Limits
1 - 60 °C
See table 3.5.B
1 - 2
1 - 99 sec
1 - 99 sec
0 - 99.5 Min
No / Yes
540876_A_PUB_DATE_1_FEB_2012.DOC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents