Primus XCONTROL PLUS Original Programming Manual page 46

Industrial washer extractors
Table of Contents

Advertisement

 THE SPRAY SEQUENCE
Prewash
| Wash | Cooldown | Rinse |
 Water or Liquid is injected at Distribution or Low Spin Speed
 No standard water inlets can be programmed in this function.
 The liquid will be injected based on soap supply programming.
Menu Item
RPM
Drain Valve
Detergents Menu...
Supply 1, ..., 8
Signal
 THE NO WASH SEQUENCE
Prewash
| Wash | Cooldown | Rinse |
 In case of a No Wash Sequence, the wash function of the programmed step is skipped.
Goto  
46
Final Rinse
| Soak |
Default
Info
-
The suggested RPM depends on the machine Type.
1
Only available on washing machines with both : a
normal Open and normal Closed Drain valve.
Time selection for Soap Boxes (hopper) and external
liquid soap supplies.
0 sec
The Spray sequence only functions with 1 Supply.
If you have programmed more then 1 supply an error
message will be generated. Put the time of the
supplies back to zero until not more than 1 non-zero
time value is remaining.
If No supply has been programmed: the Spray
sequence will be skipped.
(Liquid soap supplies must be switched on at the configuration
menu).
No
When a signal is programmed, a pause will be
introduced at the end of the Wash Step. This allows
the operator to add soap for the next step. A buzzer
signal warns the operator that the cycle has been
interrupted.
Final Rinse
| Soak | Spray |
PROGRAMOVACÍ MANUÁL
Spray
| No wash
No wash
540876_A_PUB_DATE_1_FEB_2012.DOC
Limits
See table 3.5.B
1 - 2
0 - 99 sec
No / Yes