Primus XCONTROL PLUS Original Programming Manual page 44

Industrial washer extractors
Table of Contents

Advertisement

 THE FINAL RINSE SEQUENCE
Prewash
| Wash | Cooldown | Rinse |
 No temperature can be programmed as a Last Rinse is only dedicated for cold (hard) water.
Menu Item
Inlet
Level
RPM
Detergents Menu...
Supply 1, ..., 8
On Time
Off Time
Time
Signal
44
Final Rinse
| Soak | Spray | No wash
Default
Info
I4-I7
3 Inlets can be programmed.
The suggested inlet valves are related to the
(3 inlets)
temperature and the soap box to be used.
I4
Attention!
!
(4 inlets)
If you insert other inlet valves than the suggested ones,
problems can occur at the water fill process.
Normal
The suggested water level depends on the machine
High
Type.
-
The suggested RPM depends on the machine Type.
Time selection for external liquid soap supplies.
You can program up to 4 supplies at the same time.
0 sec
If you have programmed more then 4 supplies an error
message will be generated. Put the time of the
supplies back to zero until not more than 4 non-zero
time values are remaining.
(Liquid soap supplies must be switched on at the configuration Menu)
12 sec
The wash action, motor On Time.
Gentle wash action : 3 sec.
(The suggested default values can be adjusted at the Initialization menu)
3 sec
The wash action, motor Off Time.
Gentle wash action : 12 sec.
(The suggested default values can be adjusted at the Initialization menu)
2.0 Min
The Final Rinse Sequence Time.
(for 0 Minutes the Final Rinse sequence will be skipped)
(programmable in steps of 0,5 Minutes)
No
When a signal is programmed, a pause will be
introduced at the end of the Wash Step. This allows
the operator to add soap for the next step. A buzzer
signal warns the operator that the cycle has been
interrupted.
PROGRAMOVACÍ MANUÁL
Limits
I1,2,3,4,7
See table 3.5.A
See table 3.5.B
0 - 99 sec
1 - 99 sec
1 - 99 sec
0 - 99.5 Min
No / Yes