 Programming the Motor On and Off times for Reversing
 The standard Reversing Motor On and Off times at Wash speed is 12 Seconds On and 3 Seconds Off.
 For Delicates and Woolens it's recommended to program a gentle wash action with a
Reversing On time of 3 Seconds and an Off time of 12 Seconds.
 Programming the Sequence time.
 The sequence time starts running after the water level is reached.
 If wait for Temperature has been selected, the sequence time starts only running once the
programmed temperature has been reached at the heating process.
 For a Cooldown Sequence, the programmed time corresponds with the time for decreasing the
water temperature.
Recommendation :
At least a cooldown of 3 minutes must be programmed. And to avoid the shrinking of the garments,
it's recommended to program the time so that the temperature will decrease with about 3°C for each
minute.
ATTENTION!
!
FOR A SPRAY SEQUENCE, IF A SUPPLY HAS BEEN PROGRAMMED, THE SEQUENCE TIME
CORRESPONDS WITH THE PROGRAMMED SUPPLY TIME.
 Signal
 The signal should be programmed when a running wash cycle has to be interrupted.
 The Buzzer will be activated to alert the operator.
 For most cases, the operator interrupts a program to fill the soap box an additional time.
 The program interruption will always occur at the end of a step.