Primus XCONTROL PLUS Original Programming Manual page 39

Industrial washer extractors
Table of Contents

Advertisement

 SELECTING THE WASH PART
Prewash
Spin
Type: Prewash
Wash
Prewash
|
 For a new step, as a default, the first displayed function is the Wash sequence.
 Now by pressing the ARROW LEFT or RIGHT button, you can select the desired sequence.
 Press the ENTER button to confirm.
 You can also use the ARROW DOWN button if you accept the pre-programmed default value.
 THE PREWASH SEQUENCE
Prewash
| Wash | Cooldown | Rinse |
Menu Item
Temperature
Inlet
Level
RPM
Detergents Menu...
Supply 1, ..., 8
On Time
540876_A_PUB_DATE_1_FEB_2012.DOC
 If you have selected Add Step, Edit Step or Insert Step, you
have to select the wash sequence now.
z
 Depending on the machine type, with top or front soap
dispenser, you have more or less sequences available.
| Cooldown | Rinse |
Final Rinse
Final Rinse
Default
Info
40 °C
The water temperature.
I1 - I5
The suggested inlet valves are related to the
temperature and the soap box to be used.
(40°C)
!
If you insert other inlet valves than the suggested ones,
problems can occur at the water fill process.
Normal
The suggested water level depends on the machine
Type.
Low
-
The suggested RPM depends on the machineType.
Time selection for external liquid soap supplies.
You can program up to 4 supplies at the same time.
0 sec
If you have programmed more then 4 supplies an error
message will be generated. Put the time of the
supplies back to zero until not more than 4 non-zero
time values are remaining.
(Liquid soap supplies must be switched on at the configuration
Menu)
12 sec
The wash action, motor On Time.
Gentle wash action : 3 sec.
(The suggested default values can be adjusted at the Initialization
menu)
PROGRAMOVACÍ MANUÁL
| Soak | Spray | No wash
| Soak |
Flush
| Spray | No wash
Attention!
PROGRAMMING
Limits
1 - 45 °C
I1...I8
See table 3.5.A
See table 3.5.B
0 - 99 sec
1 - 99 sec
39

Hide quick links: