SELECTING THE WASH PART
Prewash
Spin
Type: Prewash
Wash
Prewash
|
For a new step, as a default, the first displayed function is the Wash sequence.
Now by pressing the ARROW LEFT or RIGHT button, you can select the desired sequence.
Press the ENTER button to confirm.
You can also use the ARROW DOWN button if you accept the pre-programmed default value.
THE PREWASH SEQUENCE
Prewash
| Wash | Cooldown | Rinse |
Menu Item
Temperature
Inlet
Level
RPM
Detergents Menu...
Supply 1, ..., 8
On Time
540876_A_PUB_DATE_1_FEB_2012.DOC
If you have selected Add Step, Edit Step or Insert Step, you
have to select the wash sequence now.
z
Depending on the machine type, with top or front soap
dispenser, you have more or less sequences available.
| Cooldown | Rinse |
Final Rinse
Final Rinse
Default
Info
40 °C
The water temperature.
I1 - I5
The suggested inlet valves are related to the
temperature and the soap box to be used.
(40°C)
!
If you insert other inlet valves than the suggested ones,
problems can occur at the water fill process.
Normal
The suggested water level depends on the machine
Type.
Low
-
The suggested RPM depends on the machineType.
Time selection for external liquid soap supplies.
You can program up to 4 supplies at the same time.
0 sec
If you have programmed more then 4 supplies an error
message will be generated. Put the time of the
supplies back to zero until not more than 4 non-zero
time values are remaining.
(Liquid soap supplies must be switched on at the configuration
Menu)
12 sec
The wash action, motor On Time.
Gentle wash action : 3 sec.
(The suggested default values can be adjusted at the Initialization
menu)
PROGRAMOVACÍ MANUÁL
| Soak | Spray | No wash
| Soak |
Flush
| Spray | No wash
Attention!
PROGRAMMING
Limits
1 - 45 °C
I1...I8
See table 3.5.A
See table 3.5.B
0 - 99 sec
1 - 99 sec
39