Fault Concerning Memory; Faults Concerning Zero Adjust - Roland R1000 Series Manual

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0048191 / Rev. 1.5
9.2

Fault concerning memory

No.
Reason
2
Error while writing to the EEPROM.
No storage in memory possible.
3
System parameter "program number" is out of range
>255
5
System parameter "display in" is neither
mm nor inch.
6
System parameter "measuring mode" is neither
single measurement nor continuous measurement
resp. keyboard or PLC.
7
System parameter "Bus readout" is neither
mm nor inch
8
System parameter "Language" is not realistic.
9
System parameter "Number sensors" is not realistic.
11
System parameter "Measurement start" is not
realistic.
14
System parameter "FE-Measurement" is not realistic.
15
System parameter "Teach-limit FE" is not realistic.
16
System parameter "Sensor type" is not defined.
17
System parameter "Output 0-1-2" is out of range.
18
System parameter "External adjustment" is not
realistic.
19
System parameter "Bus address" is not realistic.
12
System parameter "Zero-Adjust" is not realistic.
20
Memory error XX. Unrealistic parameter in program
XX. The program has been deleted.
21
Memory error XX. Unrealistic parameter in program
XX. Several programs have been deleted.
9.3

Faults concerning Zero adjust

No.
Cause
25
The zero adjust value is not realistic.
26
The zero adjust value for FE at sensor Sx is not
realistic.
27
The zero adjust value for NF at sensor Sx is not
realistic.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Manual
Fault messages, causes and remedies
Remedy
The EEPROM is defective
The memory errors 3 to 19 (except error 12) can be
redressed as follows:
Select the defective system parameter in
the system configuration.
Press the ENTER key, the corresponding
setting will the blink.
Correct the value with the "Arrow" keys.
Store the value with the ENTER key.
Switch the unit off and on again, in
order to check the new value.
Perform Zero-Adjust
Create a new program and store it. Switch unit off and on.
If error re-appears, change EEPROM.
Since the numbers of the deleted programs cannot be
indicated, check all programs. Switch unit off and on.
If error re-appears, change EEPROM.
Remedy
Perform new zero adjust.
The Sensor might have been covered with material.
Check / exchange cable and sensor
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1000 udk20