Roland R1000 Series Manual page 48

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Mounting
4.3.7
Incorrect mounting of the PW sensors
The following illustration shows examples of incorrect installations of PW-sensors.
Fig. 20: Incorrect mounting of the PW-sensors
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
48
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Faulty!
The sensor does not touch the sheet.
Faulty!
The sensor does not sit perpendicular on the sheet, the sensor bracket is
apparently not suitable.
Faulty!
An air gap exists between the first and the second sheet.
The sensor is mounted in an unfavorable position.
Faulty!
An air gap exists between the first and the second sheet.
The second sheet clings to the first sheet, perhaps by stamping residuals.
Faulty!
Fault prone control in a bucket. An air gap exists between bended sheets.
Manual
B0048191 / Rev. 1.5