Roland R1000 Series Manual page 80

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Communication with the PLC
6.3.4
Program switching
Program switching
BIN Binary value
Measurement program
BOUT Binary value
Current measurment program
Function result)
Fig. 31: Timing diagram for program switching
*1
The switch-over times depend on the last measured material and the material to be
measured in the new program.
< 25ms for FE => FE or NF (or lm) => FE
< 170ms for NF (or LM) => NF (or LM)
< 440ms for FE => NF (or LM)
1)
In case of "Function fault" = 1 "Function result" will sometimes remain at 0.
Program no.
1
2
...
255
not used
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
80
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
BOUT
1)
BOUT
Function fault
BOUT
Ready
Note
The measured timing periods were determined with 12 Mbit- Profibus.
These timing periods can vary with different transmission rates and bus
systems. The cycle time of the PLC has not been taken into account.
Bit 7
Bit 6
Bit 5
0
0
0
0
...
...
...
1
1
1
1
Manual
< 10ms
*1
Bit 4
Bit 3
Bit 2
0
0
0
0
0
0
...
...
1
1
1
1
1
1
B0048191 / Rev. 1.5
„1" if fault
0V if fault
< 10ms
Bit 1
Bit 0
0
0
0
0
0
1
...
...
...
1
1
0
1
1
1