Electrical installation
5.2.3.9
CC-Link
The unit supports the protocol version 1 of CC-Link.
An M12 plug with A-coding is used for the CC-Link connection. A T-connector is not necessary,
because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
M12, 4-pin, A-coded, male connector at control unit
2
3
View: plug side
5.2.3.10 EtherNet/IP
The EtherNetI/P connection is implemented as 1-Port.
System in industrial enclosure
Round-shape connector, M12, 4-pin., D-coded,
socket contact at control unit (Pos. C2)
2
1
3
4
View:
Plug side
The corresponding cable plugs are part of the standard
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
60
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Note
If the UDK20 is the last participant in the bus, then an external
termination resistor should be placed into the open connector. The
resistor is not included in the scope of supply. A resistor between
DA und DB 110 Ohm or 130 Ohm ½ Watt can be used.
Allocation of CC-Link connection
Input (Pos. C2)
Pin 1
Pin 2
Pin 3
4
Pin 4
Pin 5
Suppliers / types / notes: Binder, type 715 (A-coded) and others
Pin 1
Pin 2
Pin 3
Pin 4
Plug enclosure
scope of supply.
Manual
M12, 5-pin, A-coded, female connector at control unit
SLD
DB
DG
DA
---
System as front panel mount
RJ45 – socket on circuit board
TD +
RD +
TD –
RD –
8
7
6
5
4
3
2
1
View:
Shield
Plug side
The corresponding cable plugs are not within the scope
B0048191 / Rev. 1.5
Output (Pos. C1)
1
2
5
4
3
View: plug side
Pin 1
TD +
Pin 2
TD –
Pin 3
RD +
Pin 6
RD –
Pins 4, 5, 7, 8
--
of supply.