System parameter 14: Adjusting the measuring mode.
system parameter
mode:ext. continuous
Fig. 81: Adjusting the measuring mode
Possible measurement modes:
External continuous measurement:
The system executes measurements, as long as the "Measurement start" signal is applied
via the external PLC input. For FE material the repetition time of the measurement is 0.5
seconds; for NF and LM it is less than 0.085 seconds.
External single measuring:
The system measures once if the "Measurement start" signal is applied via the external PLC
input. Each measurement must initiated separately. The hints in chapter 6.1.3.1 „timing
diagram single measurement" must be abided by.
Demo mode:
This mode of operation is intended for equipment demonstrations but not for the normal
process operation. The system executes measurements continuously. For FE material the
repetition time of the measurement is 1 second; for NF and LM it is less than 0.085 seconds.
System parameter 15: Specifying the system reaction when 2-sheet is detected.
system parameter
hold if 2sheets:
Fig. 82: Adjusting the 2-sheet reaction
Possible choice:
No:
Yes:
System parameter 16: Programming the "Measurement start" inputs under external control.
system parameter
ext. meas.start: IN0
Fig. 83: Adjusting the measurement start inputs
Possible operating conditions:
IN0:
IN0 + IN1:
IN0 + IN1 + IN2:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
14
15
no
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. The equipment does not block operation if double
sheet is encountered.
(Currently under preparation) The outputs (0-sheet, 1-sheet and 2-sheet) are
activated according to the number of sheets between the sensors. If double sheet is
detected, the output "2-sheet" is activated and the equipment is blocked until the 2-
sheet condition is cleared.
16
If 24 VDC is applied to IN0, then the measurement is executed.
If 0 VDC is applied to this input then the measurement is stopped.
The measurement is performed only, if 24 VDC is applied
simultaneously to IN0 and IN1.
The measurement takes place only, if 24 VDC is applied
simultaneously to IN0 and IN1 and IN2.