Signal "Warning"
The "Warning" signal is an additional output signal with fixed evaluation thresholds.
The signal becomes activated if the measurement result is below 80% or above 120% of the preset
nominal value.
Application:
If the "Warning" is active in the measurement, though only one sheet in front of the sensor,
measurement problems may have occurred:
•
Air gap between sensor and sheet
•
Wrong type of sheet
•
Sensor coverage not sufficient
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Note
If these requirements are met, but a warning signal is issued, then the
Teach-In must be repeated. The requirements from section "4.3 Sensor
mounting" should be observed.
Note
The signal will also be activated if measurements without a sheet
(measurement value <80%) and measurements with double sheet / two
sheets (measurement value >120%).
Manual
Communication with the PLC
95