Roland R1000 Series Manual page 117

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0048191 / Rev. 1.5
System parameter 8: Switching the password function on / off.
system parameter
password:
Fig. 75: Switching the password on / off
System parameter 9: Selecting the speed of measurement.
system parameter
FE-Measurement: fast
Fig. 76: Selecting the speed of measurement
Possible choices:
FE Measurement normal: With this kind of measuring the system reaction time depends on
the measured sheet thickness. The maximum can be inferred from the diagrams in the
chapter "2.4 Sensor data".
FE Measurement fast: Here it can be recognized whether double sheet metal rests against
the sensor before the "normal" end of the measurement. The system reaction time is shorter
and dependent on the adjusted nominal thickness as well as the upper limit value.
Disadvantage: In case of measuring results larger than the double sheet threshold, a
double sheet signal is issued instead of the actually measured values.
For NF and LM (slightly magnetic NF) the exact measuring value is always output.
System parameter 10: Specifying the type of sensor.
system parameter
sensor type:
Fig. 77: Specifying the type of sensor
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
8
yes
Attention
If no password is activated, then all parameters can be accessed at
any time. We recommend this only during starting-up the system. For
daily operation the password function should be activated.
9
10
PW42A
Note
Currently only the type of sensor PW42A is selectable.
Manual
Start-up
117