B0048191 / Rev. 1.5
4.3.8
Electromagnetic interference
Electromagnetic interference can affect the measuring accuracy of the sensor. Therefore the
sensors should not be installed close to devices which cause electromagnetic interference. Such
devices are e.g. frequency converters, servo motors or proximity switches on inductive basis. In
case of switching magnets a minimum distance of 20 mm should be observed in order to avoid
feedback.
The sensor cables should not be placed directly adjacent to cables with large interference potential,
e.g. power supply cable. This applies especially to longer cable lengths.
4.3.9
Mounting of the Sensor-Switch-Box SSBUDK10
All Dimensions are in mm. Tolerance: ± 0.4 mm.
Fig. 21: Sensor-Switch-Box SSBUDK10
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Note
The Sensor-Switch-Box SSBUDK10 should be installed in locations where
no vibration exists and no additional heat is transferred into the system
(even better reduce the heat in the control unit). Furthermore, the
Sensor-Switch-Box must be installed such that it is always accessible and
can be easily opened for service purposes. During the operation the
Sensor-Switch-Box and the sensors should be under visual control of the
operating personnel.
Manual
Mounting
49