Installation of the sensor cable
Fig. 5: Installation of the sensor cable
The following instructions are essential when installing the sensor cable:
1. Take notice of the keyway on the sensor head! Do not use during tightening a pipe
wrench or similar tools, since the pin contacts could be destroyed.
2. Be careful about the screw-in depth! Turn the cable socket until the edge flushes with
the sensor head. (see the O-ring)
3. Tighten the securing grub screw after connecting the cable socket with an allen
wrench (1.5 mm)!
2.7.2
Sensor cable extensions
A sensor cable extension can be relatively easy made. For this a SCPWS-GG or SCPWS-GW
cable is always needed.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
18
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Note
The securing grub screw is not present at every cable type