Start-up
For NF material the conductivity range is shown.
With the ENTER key and UP/ DOWN keys all ranges can be selected.
The ENTER key will exit the section.
The UP key leads to the following menu item:
system parameter
DB: <4.00 mm
Fig. 93: Setting the thickness range for the diagnosis
Here the thickness range for the diagnosis is set.
With the ENTER key and UP/ DOWN keys all ranges can be selected.
The ENTER key will exit the section.
The UP key leads to the following menu item:
system parameter
AD: 2048
Fig. 94: Indicating the thickness calculated from the characteristic curve
Here the value of the analog-digital converter and the thickness (calculated from the characteristic
curve) are shown (without Teach-In correction). For 2PW units the values for both sensors will be
shown.
The UP key leads to the following menu item:
system parameter
F= 250Hz
Fig. 95: Indicating the frequency and gain
Here the used frequency and gain is shown.
The UP key leads to the following menu item:
system parameter
sensor demagnet.
Fig. 96: De-magnetizing the sensor
Here the sensor will be de-magnetized.
The UP key leads to the following menu item:
system parameter
Fig. 97: Exiting the factor diagnosis section
The ENTER key will exit the factor diagnosis section.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
122
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
20
20
D: 1.22mm
20
V= 157
20
20
EXIT
Manual
B0048191 / Rev. 1.5