3.4.1
System parameters
"Language"
System languages available for operating the unit via display and keyboard:
German
English
Spanish
Italian
French
"Display in"
Switches the indication of the thickness values on the display between mm  inch.
"Bus readout"
Switches the out feeding of the thickness values via Field bus between mm  inch.
"Bus address"
Sets the bus address, as far as a participant address is required for Field bus. Value range 1...125
"Baud rate"
Sets the Baud rate of the Field bus (as far as required for the Field bus).
In case off EtherNet/IP: DHCP/IP/SUBNET/GATEWAY
"CLR parameter (Clear Program Parameter)"
Delete all program parameters. For doing so, the parameter needs to be set to "yes". Executing the
command requires several minutes, since the program memory will completely cleared. All
program parameters will be reset to the default values and existing Teach-In data will be deleted.
Using this function only makes sense if a unit is to be newly used for another machine.
"Password yes/no"
Switches the password request on/off. If the password request is set "on", the system / program
parameters can only be changed after the password has been entered.
"FE-Measurement fast/normal"
For time-critical applications the measuring time can be slightly shortened for measuring FE
material. If "fast" is selected and double sheet occurs, the measuring is terminated on reaching the
upper switch limit, and the information "2-sheet" is released. If "normal" is selected, the measuring
will be executed to the end and the measured thickness will be displayed.
"Sensor type"
At the time of editing the sensor type PW42A is available. For this sensor a characteristical curve
for linearization purposes exists.