Start-up
Program parameter 7: Zero adjust
program par.
zero adj.:
Fig. 53: Status of Zero adjust
Zero adjust is initiated with the ENTER key. If no zero adjust was executed or if it has to be
repeated, the menu option "on" has to be selected.
Then the following message appears (with version 2PW only):
Separate: All connected sensors must be zero adjusted individually; each sensor is
addressed individually for yes or no.
Common: All sensors are zero adjusted at the same time. In any case the zero adjust
continues with the following message, requesting to remove the sheet:
program par.
remove sheet!
Fig. 54: Removing sheet for zero adjust
After having the sheet removed, press the ENTER key. Then the following message appears
during the zero adjust:
program par.
please wait
Fig. 55: Display during zero adjust
When the zero adjust is completed, the following message appears:
program par.
zero adj.:
Fig. 56: Zero adjust successfully completed
The zero adjust is now completed.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
110
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
7
off
7
7
Note
Fault messages are described in the chapter 9. "Fault messages".
7
done