Start-up
System parameter 11: Specifying the number of connected sensors (only for 4P unit).
system parameter
number of sensors: 2
Fig. 78: Specifying the number of sensors
Possible choices:
for 2PW-unit: 1 / 2 sensors
for SSB: 1 / 2 / 3 / 4 sensors
System parameter 12: Specifying the Teach-In limits for FE.
system parameter
FE-T-Limit: 66%/125%
Fig. 79: Sensor selection
Possible choices:
66% / 125% (default setting)
33% / 142%
During Teach-In of FE material the deviation of the measured thickness from the nominal thickness
is monitored. Certain ferro-magnetic materials show a larger deviation than usual. In those cases
the 33%/142% setting instead of the default 66%/125% setting is useful. Both values represent the
permitted relative range from measured to nominal thickness. If the measuring value is not within
this range, the Teach-In cannot be performed and will be aborted with an error message.
System parameter 13: not available (reserve).
system parameter
not available
Fig. 80: Reserved system parameter
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
118
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
11
Attention
Changing the current configuration will delete all stored program
parameters. Then for all sheet types the nominal thickness values
must be re-entered and the Teach-In must be performed again.
12
13