Communication with the PLC
6.3.1
Process channel – functions and signals
Bytes 8 - 11:
Byte.Bit
8.0
8.1
8.2
8.3
8.4
8.5
8.6
8.7
9.0
9.1
9.2
9.3
9.4
9.5
9.6
9.7
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
1), 2), 3)
Footnotes see Table "Bytes 21 to 23"
Explanation of the summary output function in case of 0-sheet, 1-sheet, 2-sheet:
If the equipment is operated in the sequencer mode (program with several sensors, e.g. 1+2), then
the measurement results are issued as "summary output". The following priorities are assigned:
If one or several of the sensors issue the double sheet signal (2-sheet), then the "summary
output" is 2-sheet
If only the 1-sheet is present, then the "summary output" is 1-sheet
Otherwise the "summary output" is 0-sheet
If the results of individual sensors are required, then interrogate bytes 12-23.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
72
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
PLC → R1000 (BIN)
System test
Measurement start
Teach-In 0-sheet / zero adjust
Teach-In 1-sheet
---
Clear 2-sheet / clear 0-1-2 outputs
Program switching
Reset function fault
Bit 0 measuring program
Bit 1 measuring program
Bit 2 measuring program
Bit 3 measuring program
Bit 4 measuring program
Bit 5 measuring program
Bit 6 measuring program
Bit 7 measuring program
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Manual
R1000 → PLC (BOUT)
Function result
Current measuring program: Teach-In performed
Function fault
1)
Ready
2)
Warning
2)
0-sheet
(summary output)
2)
1-sheet
(summary output)
2)
2-sheet
(summary output)
Bit 0 current measuring program
Bit 1 current measuring program
Bit 2 current measuring program
Bit 3 current measuring program
Bit 4 current measuring program
Bit 5 current measuring program
Bit 6 current measuring program
Bit 7 current measuring program
3)
High byte thickness value
Current sensor selection A
Current sensor selection B
3)
Low byte thickness value
(sensor 1)
B0048191 / Rev. 1.5
(sensor 1)