System parameter 4: not available (reserve).
system parameter
not available
Fig. 66: Reserved system parameter
System parameter 5: Setting the bus address.
system parameter
bus address:
Fig. 67: Setting the fieldbus address
Profibus:
ControlNet:
DeviceNet:
CanOpen:
ProfiNet IO:
CC-Link:
EtherNet/IP
EtherCAT
This system parameter is only for EtherNET/IP
system parameter
EthernetIP DHCP:
Fig. 68: Setting DHCP
system parameter
IP:
192.168.
Fig. 69: Setting IP-address
system parameter
Snet:255.255.255.
Fig. 70: Setting SubNet
system parameter
GWay:
0.
Fig. 71: Setting Gateway
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
4
5
1
1 - 125
0 - 99
0 - 63
1 - 127
– –
1 – 62
– –
– –
Note for Profibus: If this adjustment is to be made in the hardware, then the bus
address can be set with the rotary switches inside the
enclosure (1 to 99). If this adjustment is to be made via
software, then the rotary switches must be turned to
address 0.
5
no
5b
0. 10
5c
0
5d
0.
0.
0
Manual
If DHCP is switched on, the IP-setting will done via
DHCP. If DHCP switched off, must the IP-address,
SubNET and Gateway be selected.
Here is the IP-address selected.
Here is the SubNet selected.
Here is the Gateway selected.