Roland R1000 Series Manual page 97

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0048191 / Rev. 1.5
6.5.5
Start continuous measurement via external input
Measurement start
Function result)
Function fault
(0-sheet, 1-sheet, 2-sheet)
(0-sheet, 1-sheet, 2-sheet)
Fig. 39: Timing diagram for start continuous measurement via external inputs
t
:
System reaction time = Measuring time ( see chapter 2.4)
s
t
:
Additional recovery time of 0.5 seconds (for FE-material)
p
1)
In case of "Function fault" = 1 "Function result" will sometimes remain at 0.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
IN / BIN
BOUT
1)
BOUT
BOUT
Ready
BOUTBus
OUT
Note
The output function result is set with the arrival of the first measured
value and remains set.
Manual
„0" active
t
t
+
t
< 5ms
s
p
s
Communication with the PLC
„1" if fault
„0" if fault
„0" active
t
t
t
t
t
t
+
+
+
< 10ms
s
p
s
p
s
p
97