STEP 22
STEP 23
Press OK.
The message window appears informing you that CALSET is completed.
Press OK.
Caution: After CALSET is completed, move the 1st axis over the full
stroke in the manual mode (speed = 10% or less) to confirm
that the positive-direction and negative-direction software
motion limits function properly. If they are valid, the axis stops
just before the mechanical end, and ERROR6071 appears.
In the following cases, reset the bolt positions, the
positive-direction software motion limits, the RANG values and
the negative-direction software motion limits to the original
settings, and repeat the procedure from the beginning:
1) The software motion limits do not function when the axis
is near a mechanical end, and another error (6111, 6121 or
6171) occurs.
2) A software motion limit error (ERROR6071) occurs
although the axis is not near a mechanical end.