3 Setting up functions
3.4 Fault services
Notice
The logical evaluation whether the timeout value is exceeded, is time-delayed by
the system. This must be taken into account if actions that can only capture
realtime data are triggered by the timeout trigger. It is not possible to capture
precisely timed data from the cycle in which the timeout took place (max. delay in
the minute range).
Due to system dependencies, repeatability of the timeout function is also linked to
the communication runtimes which depend on the demands placed on the
interface between PLC and PC of the operator. As a rule, repeats can be
implemented within a second, but expect several seconds with a high interface
load.
Fig. 3-32: Timeout trigger
Function
Name
Trigger
Start
3-134
Description
Name of the trigger: If this is not entered, the trigger
is called Timeout and assigned a consecutive num-
ber in brackets.
If the logic conditions are fulfilled for start, monitor-
ing starts for the specified time
The logic operations are created as described for
the PLC variables.
© Siemens AG 2012 All Rights Reserved
ePS Network Services, Function Manual (FH) - 03/2012
03/2012
Type
DISPLAY
INPUT
(max. 100
characters,
all characters
are
permissible)
ACTION