2.3.6 Manual Pulse Generator Input Signal (EXP+,EXP-)
The signals, EXP+ and EXP-, are used for manual pulsar signals. The following
diagram is an example connection for the external inputs.
User can set the
signals as fixed pulse CW/CCW mode, continuous pulse CW/CCW mode, or A/B
phase manual pulsar mode by using the setting in section 3.5.
Fig. 2.15 EXP+/- connection diagram
2.3.7 General Purpose Output signals(Servo On/Off)
The following diagram is a digital output signal for driver Servo On/Off signal.
The output signal enable or disable the driver.
Fig. 2.16 Servo On/Off signal connection diagram