ICP DAS USA I-8092F Getting Started Manual page 17

Pac motion control module
Hide thumbs Also See for I-8092F:
Table of Contents

Advertisement

SW 1
The emergency stop signal for each servo ampilfier can be selected from SW1. The
number 1 and 2 on SW1 are denoted as axis X and Y, respectively. The number 3 and 4
on SW1 are reserved for future work. Fig. 3-7 is the default setting to connect the EMG
singals to GND. The X-EMG and Y-EMG signal from CON4 not take effect. If the switch
is disconnected as shown in Fig. 3-8, the emergency stop signals can be controlled from
the X-EMG and Y-EMG signal in CON4.
Fig. 3-7 SW1 setting for normally GND (Default setting)
Fig. 3-8 SW1 setting for user controlled signals.
http://www.icpdas.com
17
I8092F Getting Started ManualVer.2.3