Table 113: Ip Subnet Vlan Commands - Edge-Core ECS4620-28P Cli Reference Manual

28/52-port layer 3 stackable ge switch
Hide thumbs Also See for ECS4620-28P:
Table of Contents

Advertisement

Chapter 21
| VLAN Commands
Configuring IP Subnet VLANs
Configuring IP Subnet VLANs
subnet-vlan
When using IEEE 802.1Q port-based VLAN classification, all untagged frames
received by a port are classified as belonging to the VLAN whose VID (PVID) is
associated with that port.
When IP subnet-based VLAN classification is enabled, the source address of
untagged ingress frames are checked against the IP subnet-to-VLAN mapping
table. If an entry is found for that subnet, these frames are assigned to the VLAN
indicated in the entry. If no IP subnet is matched, the untagged frames are classified
as belonging to the receiving port's VLAN ID (PVID).

Table 113: IP Subnet VLAN Commands

Command
subnet-vlan
show subnet-vlan
This command configures IP Subnet VLAN assignments. Use the no form to remove
an IP subnet-to-VLAN assignment.
Syntax
subnet-vlan subnet ip-address mask vlan vlan-id [priority priority]
no subnet-vlan subnet {ip-address mask | all}
ip-address – The IP address that defines the subnet. Valid IP addresses
consist of four decimal numbers, 0 to 255, separated by periods.
mask – This mask identifies the host address bits of the IP subnet.
vlan-id – VLAN to which matching IP subnet traffic is forwarded.
(Range: 1-4094)
priority – The priority assigned to untagged ingress traffic. (Range: 0-7,
where 7 is the highest priority)
Default Setting
Priority: 0
Command Mode
Global Configuration
Command Usage
Each IP subnet can be mapped to only one VLAN ID. An IP subnet consists of an
IP address and a subnet mask. The specified VLAN need not be an existing
VLAN.
Function
Defines the IP Subnet VLANs
Displays IP Subnet VLAN settings
– 620 –
Mode
GC
PE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents