Chapter 11
| Interface Commands
Transceiver Threshold Configuration
transceiver-threshold
current
Example
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold-auto
Console#
This command sets thresholds for transceiver current which can be used to trigger
an alarm or warning message. Use the no form to restore the default settings.
Syntax
transceiver-threshold current {high-alarm | high-warning | low-alarm |
low-warning} threshold-value
no transceiver-threshold current
high-alarm – Sets the high current threshold for an alarm message.
high-warning – Sets the high current threshold for a warning message.
low-alarm – Sets the low current threshold for an alarm message.
low-warning – Sets the low current threshold for a warning message.
threshold-value – The threshold of the transceiver current.
(Range: 0-13100 in units of 0.01 mA)
Default Setting
High Alarm:
10.50 mA
HIgh Warning: 9.00 mA
Low Warning: 2.50 mA
Low Alarm:
2.00 mA
Command Mode
Interface Configuration (SFP/SFP+ Ports)
Command Usage
◆
If trap messages are enabled with the
high-threshold alarm or warning message is sent if the current value is greater
than or equal to the threshold, and the last sample value was less than the
threshold. After a rising event has been generated, another such event will not
be generated until the sampled value has fallen below the high threshold and
reaches the low threshold.
◆
If trap messages are enabled with the
low-threshold alarm or warning message is sent if the current value is less than
or equal to the threshold, and the last sample value was greater than the
threshold. After a falling event has been generated, another such event will not
be generated until the sampled value has risen above the low threshold and
reaches the high threshold.