Siemens SCALANCE W1750D CLI Function Manual page 694

Simatic net industrial wireless lan
Table of Contents

Advertisement

CLI Commands
4.20 W
no...
Command/Parameter
wlan auth-server
<server- profile>
acct-modifier
acctport <account-
ing-port>
auth-modifier
cppm [username
<username> password
<password>]
cppm-rfc3576-only
cppm-rfc3576-port
<rfc3576- port>
deadtime <time>
drp-ip <IP-address>
<mask> vlan
<vlan> gateway
<gateway-IP- ad-
dress>
ip <host>
key <key>
nas-id <ID>
nas-ip <IP>
port <port>
radsec [port
<port>]
694
Description
Configures the external RADIUS server authenti-
cation profile.
Attributes modifier for accounting request.
Configures the accounting port number used for
sending accounting records to the RADIUS server.
Attributes modifier for access request.
Configures a username andpassword for the
ClearPass Policy Manager server
Configures a ClearPass Policy Manager server
used for AirGroup CoA with RFC3576 only.
The ClearPass Policy Manager server acts as a
RADIUS server and asynchronously provides the
Air Group parameters for the client device, includ-
ing shared user, shared role and shared location.
Configures the port number for sending AirGroup
CoA, instead of the standard CoA port.
Configures a dead time interval for the authentica-
tion server. When two or more authentication
servers are configured on the AP and a server is
unavailable, the dead time configuration deter-
mines the duration for which the authentication
server would be available if the server is marked
as unavailable.
Configures the IP address, net mask and VLAN,
which will be used as source address and VLAN
for RADIUS packets.
Before configuring DRP IP address, ensure that
dynamic-radius-proxy is enabled, and a static
virtual controller IP is configured.
Configures the IP address or the host name of the
RADIUS server.
Configures a shared key communicating with the
external RADIUS server.
Configures NAS identifier strings for RADIUS
attribute 32, which is sent with RADIUS requests
to the RADIUS server.
Configures the Virtual Controller IP address as the
NAS address which is sent in data packets.
Configures the authorization port number of the
external RADIUS server.
The RadSec command enables secure communi-
cation between the RADIUS server and AP clients
by creating a TLS tunnel between the AP and the
server.
When RadSec is enabled, the port command can
be used for specifying the communication port
number for RadSec TLS connection. By default,
the port number is set to 2083.
Range
1—1440
minutes
1-65534
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
Default
1813
5999
5
1812
2083

Advertisement

Table of Contents
loading

Table of Contents