4.16 S
Syntax
show wired-port-settings
Usage Guidelines
Use this command to view the wired profiles configured on an AP.
Example
The following example shows the output of show wired-port-settings command:
Wired Port Profiles
-------------------
Name VLAN Mode Allowed VLANs Native VLAN Admin Status Role Speed
---- --------- ------------- ----------- ------------ ---- ----
wiredProf1 Access all guest Up wired-instant auto
WiredProf2 Trunk all 1 Down WiredProf2 auto
Duplex POE In Use Authentication Method Trusted
----- ----- ---- --------------------------- -------
auto Yes Yes None
full No Yes None
Port Profile Assignments
------------------------
Port Profile Name
---- ------------
0 default_wired_port_profile
1 example1-crash
2 wired-instant
3 wired-instant
4 wired-instant
The output of this command provides the following information:
Column
Name
VLAN Mode
Allowed VLAN
618
Description
Indicates the name of the wired port profile.
Indicates the name of switchport mode for the wired profiles. The VLAN
modes can be Access or Trunk.
Indicates the list of allowed VLANs. The Allowed VLAN refers to the
VLANs carried by the port in Access mode.
SCALANCE W1750D CLI