CLI Commands
4.2 B
mode <opmode>
Parameter
config
<token>
<url>
mgmt-server
<type>
<https>
<ws>
mode <op-
mode>
62
Description
Allows you to enable BLE beacon management by
BMC.
Configures a text string of 1-255 characters as the Blue-
tooth Low Energy (BLE) endpoint authorization token.
The authorization token is used by the BLE devices in
the HTTPS header when communicating with the BMC.
Configures the URL of the server to which the BLE
monitoring data is sent.
This parameter registers the WebSocket endpoint of a
management server for BLE data, such as the Meridian
editor, on the AP. The WebSocket endpoint allows the
management server to receive messages from the BLE
relay process on the AP.
NOTE: Only one endpoint configuration is supported at
a given time. A new endpoint configuration will overwrite
the existing configuration.
URL or IP address of the HTTPS endpoint. This pa-
rameter is highly recommended for meridian load
balance.
URL of the WebSocket endpoint.
Configures the operation modes for the built-in Bluetooth
Low Energy (BLE) chip in the AP.
APs support the following BLE operation modes:
Beaconing: The built-in BLE chip of the AP functions
as an iBeacon combined with the beacon manage-
ment functionality.
Disabled: The built-in BLE chip of the AP functions in
the beaconing mode and dynamically enables
access to AP console over BLE when the link to the
LMS is lost.
DynamicConsole: The built-in BLE chip of the AP
functions in the beaconing mode and dynamically
enables access to AP console over BLE when the
link to the LMS is lost. The dynamic console mode
performs special error checks when the AP experi-
ences connectivity issues and decides if the BLE
Console needs to be enabled.
PersistentConsole: The built-in BLE chip of the AP
provides access to the AP console over BLE and
also operates in the Beaconing mode.
Range
beaconing
disabled
dynamic-
console
persistent-
console
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
Default
Disabled