CLI Commands
4.9 I
Parameter
payloadContent
rssiReporting
<type>
uidNamespaceFilter
<filter>
urlFilter <filter>
transportInterval
<interval>
username <user>
no...
Usage Guidelines
Use this command to create or modify an IoT transport profile.
176
Description
Content of the messages sent to the
IoT management server. The follow-
ing payload options are supported:
managed-beacons
Beacon management data.
managed-tags
asset tag RSSI data
zf-tags
zF tag data
all
all the BLE device data
enocean-sensors
EnOcean sensor device data
enocean-switches
EnOcean switch device data
ibeacons
iBeacon device data
unclassified
Raw data of the BLE chip
eddystone
Eddystone device data.
Sets the preferred format for RSSI
reporting.
A list of UID namespaces to filter
devices included in the reports.
Applies only Eddystone- UID devic-
es. You can specify a maximum of
10 namespaces
A list of URL strings to filter devices
included in the reports. Applies only
to Eddystone-URL devices. The
string listed here can be partial URL
strings. You can specify a maximum
of 10 URL strings.
AP IoT data interval in seconds.
Endpoint user name.
Removes any existing configuration.
Range
5 to 3600 sec-
onds
SCALANCE W1750D CLI
Function Manual, 03/2019, C79000-G8976-C452-04
Default
average
300 seconds