SIM5350 AT Command Set
AT+CEER=?
Defined values
<report>
Wrong information which is possibly occurred.
NOTE: The string refer to appendixes section "Response string of AT+CEER" of this document
Examples
AT+CEER
+CEER: Invalid/incomplete number
OK
4.6
AT+CRC Cellular result codes
Description
Write command controls whether or not the extended format of incoming call indication or GPRS
network request for PDP context activation is used. When enabled, an incoming call is indicated to
the TE with unsolicited result code "+CRING: <type>" instead of the normal RING.
Test command returns values supported by the TA as a compound value.
SIM PIN
References
YES
3GPP TS 27.007
Syntax
Test Command
AT+CRC=?
Read Command
AT+CRC?
Write Command
AT+CRC=<mode>
Defined values
<mode>
0 – disable extended format
1 – enable extended format
<type>
ASYNC
SIM5350_ATC_V1.02
OK
String type describes cause value.
Responses
+CRC: (list of supported <mode>s)
OK
Responses
+CRC:
<mode>
OK
Responses
OK
asynchronous transparent
34
6/9/2014
Need help?
Do you have a question about the SIM5350 and is the answer not in the manual?
Questions and answers