SIM5350 AT Command Set
<value>
0 CONNECT result code is given upon entering online data state. Dial tone and busy detection
are disabled.
1 CONNECT <text> result code is given upon entering online data state. Dial tone and busy
detection are disabled.
2 CONNECT <text> result code is given upon entering online data state. Dial tone detection is
enabled, and busy detection is disabled.
3 CONNECT <text> result code is given upon entering online data state. Dial tone detection is
disabled, and busy detection is enabled.
4 CONNECT <text> result code is given upon entering online data state. Dial tone and busy
detection are both enabled.
Examples
ATX1
OK
3.20
ATZ Restore the user setting from ME
Description
This command will restore the user setting from ME which set by ATE, ATQ, ATV, ATX, AT&C
AT&D, AT&S, AT\Q, AT\V, and ATS0.
SIM PIN
References
YES
3GPP TS 27.005
Syntax
Write Command
ATZ<value>
Execution Command
ATZ
Defined values
<value>
0 Set parameters to factory defaults.
Examples
ATZ0
OK
SIM5350_ATC_V1.02
Responses
OK
ERROR
Responses
Set default value: 0
OK
24
6/9/2014
Need help?
Do you have a question about the SIM5350 and is the answer not in the manual?
Questions and answers