SIM5350 AT Command Set
3.25
AT+IPR Set local baud rate temporarily
Description
This command sets the baud rate of module's serial interface temporarily, after reboot the baud rate
is set to default value. The default value is 115200.
SIM PIN
References
NO
V.25ter
Syntax
Test Command
AT+IPR=?
Read Command
AT+IPR?
Write Command
AT+IPR=<speed>
Defined values
<speed>
The rate, in bits per second, at which the DTE-DCE interface should operate. Currently, the
following
0,75,150,300,600,1200,2400,4800,7200,9600,14400,19200,28800,38400,57600,115200,230400,46
0800,921600. If unspecified, or set to zero, automatic detection is selected, and the character format
is forced to auto detect.
Examples
AT+IPR?
+IPR: 115200
OK
AT+IPR=?
+IPR:(0,75,150,300,600,1200,2400,4800,7200,9600,14400,19200,28800,38400,57600,115200,230
400,460800,921600)
OK
AT+IPR=115200
OK
SIM5350_ATC_V1.02
Responses
+IPR: (list of supported<speed>s)
OK
Responses
+IPR:
<speed>
OK
Responses
OK
ERROR
rates
26
are
supported:
6/9/2014
Need help?
Do you have a question about the SIM5350 and is the answer not in the manual?
Questions and answers