SDC790A
Use the Arrow Buttons to select the material loading orientation:
1
2
3
4
Press Green to confirm your selection. The display requests the scanning
version:
018>
Vers.: OMR DI900/DI950
<-->=SELECT
Use the Arrow Buttons to select which scanning mode you want. In this
example, select 'OMR DI900/DI950'.
Press Green to confirm. The display requests the OMR scanner location:
018> OMR location : BOTTOM-FRONT
Green=CONFIRM
If you have more than one scanning head fitted to your system, you must
now tell the system which scanning head to use for this job.
If you only have one scanning head, this step is not required.
Use the Arrow Buttons to select where the OMR scanner is located:
Bottom Rear, Bottom Front, Top Rear or Top Front.
Press Green to confirm. The display shows the scan line increment
selection:
018>
Scan line increments : 1/6 Inch
<-->=SELECT
Use the Arrow Buttons to select the scan line increments. You can select
one of the three (1/6", 1/8" or 1/10") scan line increments shown, or you can
select a custom 'User Defined' increment. Press Green to confirm.
If you select 'User Defined', you must now enter the increment:
018>
Scan line increments : --- [0.01MM]
<-->=SELECT
Take a sample of your OMR with the largest number of scan lines you can
obtain. Measure the length of the code in millimetres, and then divide this by
the number of gaps between lines to obtain an average increment.
Face up, bottom first
Face up, top first
Face down, bottom first
Face down, top first
Green=CONFIRM
Green=CONFIRM
Green=CONFIRM
Programming • 3
Blue=EXIT
Blue=EXIT
Blue=EXIT
Blue=EXIT
3-7

Advertisement