Bfm#32] Positioning Parameter Selection; Bfm#34, #33] Pulse Rate; Bfm#36, #35] Feed Rate - Mitsubishi Electric MELSEC-F Series User Manual

Hide thumbs Also See for MELSEC-F Series:
Table of Contents

Advertisement

FX
-1PG User's Manual
3U

7.3.12 [BFM#32] Positioning parameter selection

Select whether the positioning parameter (BFM#0 to #15) is used or the extension positioning parameter
(BFM#33 to #52) is used.
BFM No.
High order
Low order
16bit
16bit
-
Point
• When the parameter is changed during the operation, the change becomes valid from the next operation.
• Set the positioning parameter to the buffer memory that corresponds to the selected positioning parameter.

7.3.13 [BFM#34, #33] Pulse rate

Set the number of pulses required to rotate the motor for one turn.
Setting is necessary when the unit system is set to "machine system unit" or "combined system unit."
When "motor system unit" is selected, the setting here will be ignored.
BFM No.
High order
Low order
16bit
16bit
#34
Point
• If any electronic gearing is present in the servo amplifier, it is necessary to consider its effect.
The relationship between pulse rate and electronic gearing is shown below.
Pulse rate = Resolution power of encoder (positioning feedback pulses) ÷ Electronic gearing
• When the positioning parameter is used, use the pulse rate (BFM#0).

7.3.14 [BFM#36, #35] Feed rate

Set the travel distance of the machine for one turn of the motor.
Setting is necessary when the unit system is set to "machine system unit" or "combined system unit."
When "motor system unit" is selected, the setting here will be ignored.
BFM No.
High order
Low order
16bit
16bit
#36
Point
When the positioning parameter is used, use the feed rate (BFM#2, #1).
64
b0 = OFF (0): Positioning parameter (BFM#0 to #15) is used
#32
b0 = ON (1): Extension positioning parameter (BFM#32 to #52) is used
b1 to b15: Not used
#33
Setting range: 1 to 2,147,483,647 PLS/REV
#35
Setting range: 1 to 2,147,483,647 (μm/REV, mdeg/REV, 10
Description
→ For details on the system of units, refer to Subsection 7.3.15.
Description
→ For details on the system of units, refer to Subsection 7.3.15.
Description
7 Buffer Memory
7.3 Positioning Parameters
R/W
R/W
R/W
R/W
R/W
-4
R/W
inch/REV)
Default
H0000
Default
K2,000
Default
K1,000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u-1pg