FX
-1PG User's Manual
3U
BFM No.
High
Low
order
order
16bit
16bit
#24
#23
-
#25
#27
#26
-
#28
-
#29
-
#30
-
#31
Buffer memories BFM#32 and later are new in the FX
Refer to Section 7.2 for the contents of buffer memories BFM#32 and later.
Item
1 to 2,147,483,647 (user unit)
Operation speed ΙΙ
Set the value within 1 to 200,000 Hz when
converted to pulse data.
b0: Error reset
b1: STOP
b2: Reverse limit
b3: Reverse limit
b4: Forward JOG operation
b5: Reverse JOG operation
b6: DOG type mechanical zero return operation start
b7: Relative/absolute address
b8: 1-speed positioning operation start
Operation command
b9: Interrupt 1-speed positioning operation start
b10: 2-speed positioning operation start
b11: External command positioning operation start
b12: Variable speed operation
b13: Interrupt stop operation start
b14: Interrupt 2-speed positioning
operation start
b15: Data-set type mechanical zero return
operation start
Current address
-2,147,483,648 to 2,147,483,647 (user unit)
b0: READY
b1: Forward/Reverse
b2: Zero return completion
b3: STOP input ON
b4: DOG input ON
b5: PG0 input ON
b6: Current value overflow
Status information
b7: Error flag
b8: Positioning completion flag
b9: 1-speed completion flag
b10: Interrupt input 0 ON
b11: Interrupt input 1 ON
b12: Remaining distance operation waiting b12: Not used
b13 to b15: Not used
Error code
An error code is stored at the time of the error occurrence.
Model code
K5,130
Not used
Not used
3U
Appendix C: Differences with FX2N-1PG
Appendix C-2 Differences of Buffer Memory
Setting range
FX
-1PG
3U
-1PG.
FX
-1PG
2N
1 to 153,000 (user unit)
Set the value within 10 to 100,000 Hz
when converted to pulse data.
b13: Not used
b14: Not used
b15: Not used
b9: Not used
b10: Not used
b11: Not used
K5,110
Not used
11
A
B
C
131