Download Print this page

Mitsubishi Electric MELSEC-F FX3U-4AD-ADP User Manual

Advertisement

Quick Links

JY997D13901N
Side
JAPANESE
A
Side
ENGLISH
B
FX
-4AD-ADP
3U
USER'S MANUAL
Manual Number
JY997D13901
Revision
N
Date
May 2018
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective May 2018
Specifications are subject to change without notice.
©
2005 Mitsubishi Electric Corporation
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
Describes specifications for
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
JY997D16701
analog control and
FX
Series
3UC
MODEL CODE:
programming method for
User's Manual
FX
/FX
/FX
/FX
09R619
3S
3G
3GC
- Analog Control Edition
FX
3UC
Series PLC.
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
FX
Series
JY997D16601
3UC
Describes PLC programming
Programming Manual
MODEL CODE:
for basic/applied instructions
- Basic & Applied
09R517
and devices.
Instruction Edition
FX
Series
JY997D48601
Explains FX
Series PLC
3S
3S
User's Manual
MODEL CODE:
specifications for I/O, wiring,
installation, and maintenance.
- Hardware Edition
09R535
FX
3G
Series
JY997D31301
Explains FX
Series PLC
3G
User's Manual
MODEL CODE:
specifications for I/O, wiring,
installation, and maintenance.
- Hardware Edition
09R521
FX
Series
JY997D45401
3GC
Explains FX
3GC
Series PLC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
- Hardware Edition
09R533
installation, and maintenance.
FX
Series
JY997D16501
Explains FX
Series PLC
3U
3U
User's Manual
MODEL CODE:
specifications for I/O, wiring,
installation, and maintenance.
- Hardware Edition
09R516
FX
3UC
Series
JY997D28701
Explains FX
Series PLC
3UC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
installation, and maintenance.
- Hardware Edition
09R519
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
Side
B
Applicable standards
FX
-4AD-ADP
3U
units made in June, 2005 or later comply with the EC Directive (EMC
Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.
→ FX
3S
Series Hardware Manual (Manual No. JY997D48301)
→ FX
Series Hardware Manual (Manual No. JY997D46001)
3G
→ FX
3GC
Series Hardware Manual (Manual No. JY997D45201)
→ FX
Series Hardware Manual (Manual No. JY997D50301)
3U
→ FX
(D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)
3UC
→ FX
3UC
-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)
Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Attention
This product is designed for use in industrial applications.
Caution for EC Directive
The analog special adapters have been found to be compliant to the European
standards in the aforesaid manual and directive. However, for the very best per-
formance from what are in fact delicate measuring and controlled output device
Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered care-
fully. For users of proprietary cables (integral with sensors or actuators), these
users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other
EMC protection is provided, then users may experience temporary loss or
accuracy between ±10 % in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are fol-
lowed for the users complete control system, users should expect accuracy as
specified in this manual.
• Sensitive analog cable should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible users should run analog
cables separately.
• Good cable shielding should be used. When terminating the shield at Earth
- ensure that no earth loops are accidentally created.
• When reading analog values, EMC accuracy can be improved out by
averaging the readings. This can be achieved either through functions on the
analog special adapters or through a users program.
1. Outline
The FX
-4AD-ADP special adapter for analog input (hereinafter called 4AD-ADP) is a
3U
special adapter to add four analog input points.
1.1 Incorporated Items
Verify that the following product and items are included in the package:
may
Product
FX
-4AD-ADP analog input special adapter
3U
Accessories User's manual (This manual)
/
3U
1.2 External Dimensions, Part Names, and Terminal Layout
[10]
[5]
[3]
[4]
[6]
[2]
[7]
[8]
[1]
7(0.28") 74(2.92")
15.1
15.5
[9]
(0.62")
(0.6")
[11]
17.6
(0.7")
Special adapter
connector cover
is removed
Weight: Approx. 0.1 kg (0.22 lbs)
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock:
Used to connect additional special adapters onto the left side of this special
adapter.
[4] Special adapter connector cover:
Remove this cover to connect additional special adapters to the left side.
[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
Not used when connecting to FX
/FX
Series PLC.
3GC
3UC
[6] POWER LED (green):
Lit while 24 V DC power is supplied properly to terminals '24+' and '24-'.
[7] Terminal block (European type):
Connect the analog voltage/current signal, and 24 V DC power supply.
[8] Special adapter connector:
Used to connect this special adapter to PLC main unit or special adapter.
[9] DIN rail mounting hook
[10] Special adapter fixing hook
[11] Special adapter connector:
Used to connect communication or analog special adapters to the left side of the
4AD-ADP.
2. Installation
For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.
INSTALLATION
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
, H
S, SO
, or NO
), flammable gas, vibration or
2
2
2
2
impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
• Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.
2.1 Connection to the PLC
This section describes the connection method to the PLC (FX
24+
used for the following example).
24-
For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.
V1+
Procedure
1) Turn off the power.
I1+
Disconnect all the cables connected to the PLC main unit and special adapter,
COM1
and demount the main unit and special adapter mounted on DIN rail or
V2+
mounted directly using screws.
I2+
2) Install an expansion board to the main unit.
For the expansion board installation procedure, refer to the following manual:
COM2
→ FX
Series User's Manual - Hardware Edition
3U
V3+
3) Remove the special adapter connector cover
I3+
on the expansion board (fig.A).
When connecting this product to another
COM3
special
adapter,
please
replace
the
4)
V4+
'expansion board' in the above description
I4+
with a 'special adapter' and perform the
COM4
procedure as indicated.
B
4) Slide the special adapter slide lock
(fig.B) of the main unit.
When connecting this product to another
special adapter, please replace the 'main
A
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated. (Please replace the following
procedures similarly.)
5) Connect the
B
special adapter
(fig.C) to the
C
main unit as
6)
shown on the
right.
6) Slide back the
special adapter
5)
slide lock (fig.B)
of the main unit
to fix the special
5)
adapter (fig.C).
5)
Connection precautions
Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of any
special adapters other than other high-speed I/O special adapters.
3U
Series PLC is
3)
4)
B
6)
B

Advertisement

loading

Summary of Contents for Mitsubishi Electric MELSEC-F FX3U-4AD-ADP

  • Page 1 Store this manual in a safe place so that it can be taken out and read whenever (0.7") When connecting this product to another Special adapter Mitsubishi Electric recommend that shielded cables should be used. If NO other necessary. Always forward it to the end user. connector cover special adapter, please replace the 'main...
  • Page 2 (The data will be updated at every scan time of the PLC.) Doing so may cause fire, equipment failures, or malfunctions. nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 3) Termination of cable end * For repair, contact your local Mitsubishi Electric representative.
  • Page 3 (0.7") Special adapter When connecting this product to another Mitsubishi Electric recommend that shielded cables should be used. If NO other necessary. Always forward it to the end user. connector cover special adapter, please replace the 'main...

This manual is also suitable for:

Melsec-f fx3u series