Bfm#86][Bfm#126][Bfm#166][Bfm#206] Transistor Output Selection - Mitsubishi Electric MELSEC FX Series User Manual

Programmable controllers
Hide thumbs Also See for MELSEC FX Series:
Table of Contents

Advertisement

FX
-4LC User's Manual
3U

8.2.50 [BFM#86][BFM#126][BFM#166][BFM#206] Transistor output selection

To these buffer memories, set the function of transistor outputs built into the 4LC.
Available transistor output functions vary depending on the control mode setting.
BFM No.
CH1 CH2 CH3 CH4
#86
#126 #166 #206 Setting range : 0 to 7 (Refer to the following)
Transistor output selection
Transistor
output
0, 1 : PID control
selection
(Internal output)
set value
OUT1
CH1 control output
OUT2
CH2 control output
0
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
1
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
2
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
3
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
4
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
5
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
6
OUT3
CH3 control output
OUT4
CH4 control output
OUT1
CH1 control output
OUT2
CH2 control output
7
OUT3
CH3 control output
OUT4
CH4 control output
*1.
When selecting the control mode "4" or "5", use external output for CH2 and CH4.
Caution
It is not possible to change the setting while control is being performed. If the setting is changed while control
is being performed, the contents of setting are reflected when control is stopped.
108
→ For details on the control mode switch, refer to Section 6.2.
→ For details on the transistor output selection function, refer to Section 6.3.
Description
2, 3 : PID control
(External output)
Normally OFF
Normally OFF
Normally OFF
Normally OFF
CH1 control output
CH2 control output
CH3 control output
CH4 control output
CH1 control output
CH2 control output
CH3 control output
CH4 control output
CH1 alarm 1 state
CH2 alarm 1 state
CH3 alarm 1 state
CH4 alarm 1 state
CH1 alarm 2 state
CH2 alarm 2 state
CH3 alarm 2 state
CH4 alarm 2 state
CH1 alarm 3 state
CH2 alarm 3 state
CH3 alarm 3 state
CH4 alarm 3 state
CH1 alarm 4 state
CH2 alarm 4 state
CH3 alarm 4 state
CH4 alarm 4 state
CH1 loop breaking alarm state
CH2 loop breaking alarm state
CH3 loop breaking alarm state
CH4 loop breaking alarm state
Control mode
4, 5 : Heating/cooling
PID control
*1
(Internal output)
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
CH1 heating control output
CH1 cooling control output
CH3 heating control output
CH3 cooling control output
8 Buffer Memory
8.2 Buffer Memory Details
Initial
R/W
Backup
value
0
R/W
6, 7 : Heating/cooling
PID control
(External output)
Normally OFF
Normally OFF
Normally OFF
Normally OFF
CH1 heating control output
CH2 heating control output
CH3 heating control output
CH4 heating control output
CH1 cooling control output
CH2 cooling control output
CH3 cooling control output
CH4 cooling control output
CH1 alarm 1 state
CH2 alarm 1 state
CH3 alarm 1 state
CH4 alarm 1 state
CH1 alarm 2 state
CH2 alarm 2 state
CH3 alarm 2 state
CH4 alarm 2 state
CH1 alarm 3 state
CH2 alarm 3 state
CH3 alarm 3 state
CH4 alarm 3 state
CH1 alarm 4 state
CH2 alarm 4 state
CH3 alarm 4 state
CH4 alarm 4 state
Normally OFF
Normally OFF
Normally OFF
Normally OFF

Advertisement

Table of Contents
loading

Table of Contents