Data-Set Type Mechanical Zero Return Operation - Mitsubishi Electric MELSEC-F Series User Manual

Hide thumbs Also See for MELSEC-F Series:
Table of Contents

Advertisement

FX
-1PG User's Manual
3U
8.3.3

Data-set type mechanical zero return operation

Data-set type mechanical zero return is the zero return method that is used to set the position, which is
traveled by the JOG operation etc., as a zero position. Therefore, the work piece does not move when the
data-set type mechanical zero return command is turned on.
This zero return method is often used in equipment for which the DOG cannot be used or in the transfer line
that does not have a mechanical zero position.
1. Operation
1) Move the work piece to the position to be set as a zero position, by the JOG operation etc.
2) Set the data-set type mechanical zero return operation start from off to on. (It outputs the CLR signal.)
3) The set value of the zero-point address is written to the current address.
4) The zero return completion turns on.
In case of the data-set type zero return, the positioning completion flag does not turn on.
2. Positioning completion flag
Turns on when the zero return is completed and after the zero-point address is written to the current address.
Turns off when the power is turned off or when K0 is written to the status information. It does not turn off when
the operation is started.
3. Positioning completion flag
The positioning completion flag turns off when the data-set type mechanical zero return operation starts.
The positioning completion flag does not turn on when the zero return operation is completed.
Setting items of the data-set type mechanical zero return operation
BFM No.
Positioning
parameter
#3 b1, b0
#3 b5, b4
#14, #13
#25 b15
#28 b2
88
Extension
positioning
parameter
#37 b1, b0
Operation parameter
#37 b5, b4
#50, #49
Zero-point address
Operation command
Status information
8.3 Mechanical Zero Return Operation
→ For details on the JOG speed, refer to Section 8.2.
Setting items
System of units
Position data multiplier
Data-set type mechanical zero return
operation start
Zero return completion
8 Manual Control