9.8

Interrupt 2-speed Positioning Operation

By the interrupt 2-speed positioning start command, the operation starts with operation speed I. After
detecting the rise/fall edge of interrupt input 0, the operation speed changes to operation speed II. Then, after
the rise/fall edge of interrupt input 1 is detected, the operation decelerates and stops at target address I.
1. Operation
1) Set operation speed I, operation speed II, and target address I.
2) When the interrupt 2-speed positioning operation start of the operation command is turned from off to on,
the interrupt 2-speed positioning operation in operation speed I starts. (The positioning completion flag
turns off).
3) When interrupt input 0 is detected, the speed changes to operation speed II.
4) When interrupt input 1 is detected, traveling is executed for the amount set to the target address I with
operation speed II, and the operation completes by turning on the positioning completion flag.
Interrupt 2-speed
positioning
operation start
(BFM#25 b14)
Interrupt input 0
Interrupt input 1
1-speed completion flag
(BFM#28 b9)
Positioning
completion flag
(BFM#28 b8)
READY
(BFM#28 b0)
Current address
(BFM#27, #26)
Point
• When interrupt input 1 is detected before interrupt input 0 is detected, interrupt input 1 is ignored.
• The current address is cleared by interrupt 2-speed positioning operation start command. After detecting
interrupt input 1, the current address starts changing.
• When the travel amount is 0, the positioning operation is not executed even when the interrupt 2-speed
positioning operation start is turned on. In addition, the positioning completion flag also does not change.
READY turns off only instantaneously.
108
Speed
Operation speed I
Bias speed
Acceleration/
deceleration time
(Acceleration time)
ON
OFF
OFF
ON
ON
9.8 Interrupt 2-speed Positioning Operation
→ For change of the operation speed, refer to Section 6.6.
→ For change of the target address, refer to Section 6.7.
→ For details on the STOP command, refer to Section 6.5.
Maximum speed
Operation speed II
Target address I
ON
OFF
ON
OFF
ON
OFF
OFF
0 → Target address I
0
9 Positioning Control
Time
Acceleration/
deceleration time
(Deceleration time)
OFF
ON
ON
Target address I